70
8.6.3
Max Cornering Force (ID=1604)
It is max allowed cornering angle which can be reached while cornering without triggering
harsh cornering event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0.1
1.0
-
U16
8.6.4
Max allowed Speed (ID=1605)
It is max allowed speed which can be reached. If this value exceeded Over speeding event
will occur.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
260
-
U16
8.6.5
Digital Output No.2 usage scenarios (ID=1601)
Device can operate in its scenario according to selected value: No Scenario for Digital No.2
selected (value 0); Authorized Driving (value 1), Immobilizer (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
8.6.6
Trip (ID=1280)
This parameter enables ability to detect START and STOP of the trip.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U8
8.6.7
Start Speed (ID=1281)
This parameter represents speed, which is detected as minimum speed to indicate TRIP
START and generate event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
U8
8.6.8
Ignition Off Timeout (ID=1282)
This parameter represents timeout to wait if ignition is off in order to detect TRIP STOP and
generate event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
-
U16
Содержание FM1120
Страница 33: ...33 Figure 25 Data Acquisition Mode configuration...