68
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
U32
8.5.6.2
Min Distance (ID=1591)
This parameter indicates distance in meters in order to acquire new record. Record is
stored when the distance between previous records is greater than parameter’s value. If value is
0 it means no records by min distance will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
-
U32
8.5.6.3
Min Angle (ID=1592)
This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
180
-
U16
8.5.6.4
Min Speed (ID=1596)
This parameter indicaes speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min distance will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
1
U16
8.5.6.5
Min Speed Source (ID=1597)
This parameter defines Source for speed difference calculation: 0 – GPS, 1 – LVCAN
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
0
U8