69
9.6
Features Parameters
9.6.1
Scenarios Enable (ID=1600)
Device can operate in its scenario according to selected value: No Scenario selected (value
0); Green Driving selected (value 1), Overspeeding selected (value 2), Green Driving &
Overspeeding selected (value 3).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
-
U8
9.6.2
Max Acceleration Force (ID=1602)
It is max allowed acceleration force which can be reached while accelerating without
triggering harsh acceleration event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0.25
0.85
0.25
Float
9.6.3
Max Braking Force (ID=1603)
It is max allowed braking force which can be reached while braking without triggering
harsh braking event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0.25
0.85
0.35
Float
9.6.4
Max Angular Velocity (ID=1604)
It is max allowed cornering angle which can be reached while cornering without triggering
harsh cornering event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0.1
1.0
-
U16
9.6.5
Max allowed Speed (ID=1605)
It is max allowed speed which can be reached. If this value exceeded Over speeding event
will occur.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
260
-
U16
9.6.6
Excessive Idling detection (ID=1607)
If ignition is ON and no movement, event will be generated when TMO reached. This
functionality is 1
–
enabled, 0
–
disabled (default).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
Time to stationary (ID=1608)
U8