57
1
3000
-
U8
9.2.3
Mode Switch Source (ID=1002)
Device can operate and change its working mode according to motion detection source:
ignition (value 0), movement (value 1), GNSS (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
9.2.4
Ignition Source (ID=1003)
Device can operate and change its working mode according to motion detection source:
Power Voltage (value 0), Digital Input 1 (value 1), movement (value 2), OBD(value 3).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
Power Voltage Low Level
(ID=1006)
Power Voltage Level High Level
(1007)
U8
9.2.5
Static navigation settings (ID=1004)
When static navigation is enabled, FM1000 filters out GPS jumps, when it is not moving.
When it is disabled, it does not make any changes to collected GPS data. 0 - disabled (default); 1 -
enabled.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U8
9.2.6
Saving/Sending without time synchronization (ID=1005)
When this feature is enabled (value = 1), then records can be saved and sent to server
without time synchronization.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
U8
9.2.7
Power Voltage Low Level (ID=1006)
When ignition source is selected as Power Voltage Low level for ignition detection must be
set.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
30000
-
Ignition Source (ID=1003)
Power Voltage Level High Level
(1007)
U16