36
Figure 22 Scenarios configuration
Green Driving. Eventual Record is generated when Max Acceleration force, Max
Braking Force or Max Cornering Force exceeds configured parameters value.
Over Speeding. Eventual Record is generated when vehicle speed exceeds
configured parameters value.
Excessive Idling Detection. If ignition is ON and no movement, event will be
generated when TMO reached. User can enable this functionality, select timeouts for stationary
time and for movement time.
Jamming Detection. User can select Jamming detection sensitivity (RSSI -Received
signal strength indication threshold): Low(50RSSI), Normal(30RSSI), High(10RSSI) and Disable this
functionality.
Alarm.
Eventual Record is generated when Alarm button is pressed. Pressing button
for 3
–
5 seconds
–
alarm record sent, pressing button for 6-9 seconds
–
alarm record canceled.
Unplug Detection. Eventual event will be generated when FM1000 is unplugged
from OBD socket. User can select detection type: simple
–
used in cars, where power voltage is
not dependant on ignition (recommended); advanced
–
used in cars, where power voltage is
disconnected when ignition is switched off.
Crash detection. Eventual Record is generated when device detects car accident
using the internal sensors (Accelerometer). Crash detection functionality can be set according to
these settings:
•
Threshold (mg)
•
Duration (ms)
If accident happens and FM detects acceleration value higher than set threshold value
during set time period, then FM will generate an event. Threshold and duration values are set
depending of accident power which you want to detect. FM can detect a slight tapping on the
device (Threshold=100mg, Duration=1ms) or can detect severe accident (Threshold=4000mg,
Duration=5ms). When crash is detected, car Crash Detection functionality starts timeout (5sec.),
during which the new Crash detections events are not stored.