Confidential
MTP7632 Programming Manual
Telpar 800-872-4886 39 -
[Range]
10
≤
( pL + pH
×
256)
≤
65530
(where ( pL + pH
×
256) = 9
×
k + 1
:
0
≤
pL
≤
255
;
0
≤
pH
≤
255)
m = 3
1
≤
a
≤
8
b = 48, 49,50
1
≤
k
≤
7281
[Description]
Changes the setting of the memory switch specified with a using the value of b
b Function
48
Sets the specified bit to 0
49
Sets the specified bit to 1
50
Does not change the previous status of the specified bit
•
The total bits of the memory switch is 8.
• The value of b is processed in order of bit 8 to bit 1;
• If an error occurs in the process of writing data, the memory error process is execute.
• Set
b as
“
2
”(
50
)
to the reserved bit.
• If the settings are changed, they become effective when the BA-T500 is reset other
power is turned on again.
•
The setting values can be checked by executing the self-test.
GS ( E pL pH m a (m = 4) <Function 4>
[Format]
ASCII GS
(
E p
L
p
H
m a
Hex
1D
28
45
p
L
p
H
04 a
Decimal 29
40
69 p
L
p
H
4 a
[Range]
( p
L
+ p
H
×
256) =2 ( p
L
= 2
,
p
H
= 0)
m = 4
1
≤
a
≤
8
[Function]
Sends the setting values of the memory switch specified with a
The contents of the transmit data are as follows
:
Transmit data Hex
Decimal
Number of data
①
Header
37H 55
1
byte
②
Flag
21H 33
1
byte
③
Data
30H, 31H
48, 49
8 bytes
④
NUL
00H 0 1
byte
Contents of data shown in
③
above
:
The on/off setting of the memory switch is defined as [Off: Hex=30H/Decimal=48]
or[On:Hex=31H/Decimal=49].Each 1 byte for 8 memory switches are transmitted from bit 8
to bit 1.
Example
:
Transmitted data:“10110001”
(31H, 30H, 31H, 31H, 30H, 30H, 30H, 31H)
Содержание MTP7632
Страница 85: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 79 Code Page 1 Katakana ...
Страница 86: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 80 Code Page 2 PC850 Multilingual ...
Страница 87: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 81 Code Page 3 PC860 Portuguese ...
Страница 88: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 82 Code Page 4 PC863 Canadian French ...
Страница 89: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 83 Code Page 5 PC865 Nordic ...
Страница 90: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 84 Code Page 16 WPC1252 ...
Страница 91: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 85 Code Page 17 PC866 Cyrillic 2 ...
Страница 92: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 86 Code Page 18 PC852 Latin2 ...
Страница 93: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 87 Code Page 19 PC858 ...