Confidential
MTP7632 Programming Manual
Telpar 800-872-4886 45 -
operation range specified by
GS C 1
or
GS C
;, it is forced to convert to the minimum
value
.
In count-down mode, if the counter value specified by this command goes out of the counter
operation range specified by
GS C 1
or
GS C
;, It is forced to convert to the maximum value
.
[
Default
]
nL = 1, nH = 0
[
Reference
]
GS C 0, GS C 1, GS C ; GS c
GS C ; sa ; sb ; sn; sr; sc;
[
Name
]
Select count mode
(Β)
[
Format
]
ASCII GS
C ; sa ; sb ; sn ; sr ; sc ;
Hex
1D
43 3B sa 3B sb 3B sn 3B sr 3B sc 3B
Decimal 29
67 59 sa 59 sb 59 sn 59 sr 59 sc 59
[
Range
]
“0”
≤
sa
≤
“65535”
“0”
≤
sb
≤
“65535”
“0”
≤
sn
≤
“255”
“0”
≤
sr
≤
“255”
“0”
≤
sc
≤
“255”
These values are all character strings
.
[
Description
]
Select a count mode for the serial number counter
.
•
sa, sb, sn, sr and scare all displayed in ASCII characters, using the codes for "0" to
"9".
•
sa and sb set the counter range.
•
sn indicates the stepping amount of counting up or down.
•
sr indicates the repetition number with the counter value fixed.
•
sc indicates the counter value.
[Νο
tes
]
•
Count-up mode is specified when
:
sa < sb ,sn
≠
0 , sr
≠
0.
Count-down mode is specified when
:
sa > sb , sn
≠
0 , sr
≠
0.
Count stop when
:
sa = sb or sn = 0 or sr = 0.
When count-up mode is specified, sa is the minimum counter value and sb is the maximum
counter value. If the counter value set by sc is outside the counter operation range, the counter
value is forced to convert to the minimum value.
When count-down mode is specified, sa is the maximum counter value and sb is the minimum
counter value. If the counter value set by sc is outside the counter operation range, the counter
value is forced to convert to the maximum value.
Parameters
sa to sc
can be omitted. If omitted, these argument values are unchanged.
Parameters
sa to sc
must not contain characters, except 0 to 9.
If an incorrect syntax is used, the corresponding parameter setting has no effect, and the data
after that is processed as normal data.
[
Default
]
sa = 1, sb = 65535, sn = 1, sr = 1, sc = 1
Содержание MTP7632
Страница 85: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 79 Code Page 1 Katakana ...
Страница 86: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 80 Code Page 2 PC850 Multilingual ...
Страница 87: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 81 Code Page 3 PC860 Portuguese ...
Страница 88: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 82 Code Page 4 PC863 Canadian French ...
Страница 89: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 83 Code Page 5 PC865 Nordic ...
Страница 90: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 84 Code Page 16 WPC1252 ...
Страница 91: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 85 Code Page 17 PC866 Cyrillic 2 ...
Страница 92: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 86 Code Page 18 PC852 Latin2 ...
Страница 93: ...Confidential MTP7632 Programming Manual Telpar 800 872 4886 87 Code Page 19 PC858 ...