Page 28
Paper Low
1) When a PAPER LOW state is detected, the data receive and
printing continue to function.
2) The PAPER LOW function is disabled when the power is turned
on or the printer is initialized. It can be enabled with the FS 9
+n
command.
3) If the PARALLEL interface is used and the PAPER LOW
detector is enabled, a PAPER LOW condition is treated as a
PAPER OUT condition.
When the detection connector is open, the PAPER LOW state is
assumed.
Head Up
1) When the HEAD UP lever is raised during printing, the head
drive and motor drive operations are stopped. For the SERIAL
INTERFACE: If Xon/Xoff flow control is selected, Xoff is
transmitted. If DTR/DSR flow control is selected, the DTR
signal goes to “mark” (BUSY) state.
2) When the print head is lowered, one line is fed after
approximately 1 second then printing resumes.
3) When the HEAD UP function is disabled by the FS 9
+n
command or the *SLTIN signal, the HEAD UP function is not
executed. . For the SERIAL INTERFACE: If Xon/Xoff flow
control is selected then Xon is transmitted. If DTR/DSR flow
control is selected, then the DTR signal goes to “space”
(READY) state.
4) When the HEAD UP function is enabled, paper cannot be fed
with a command but can be fed with the Paper Feed push
button.
Print Head
Thermal
Error
1) The temperature of the thermal head is detected by the
thermistor built into the thermal head to prevent the thermal
head from overheating.
2) If an abnormal temperature (excessively high temperature) is
detected, the thermal head is set to the busy state. The busy
state is maintained until the temperature is reduced to the
specified temperature.
3) When the PRINT HEAD TEMRERATURE is disabled by the FS
9
+n
command, the temperature fault function is not executed.
4) If the PRINT HEAD TEMRERATURE is abnormal and the
function is enabled, paper cannot be fed with a command but
can be fed with the Paper Feed push button.
5) If the temperature of the thermal head falls to the printing
enable level, the printer immediately returns to the normal state
when there are no other errors.
Blown
Fuse
Detection
Function
1) When the system detects that the fuse for motor protection has
blown, . For the SERIAL INTERFACE: If Xon/Xoff flow control is
selected then Xoff is transmitted. If DTR/DSR flow control is
selected the DTR signal goes to the “mark” (BUSY) state.
2) Turn off the power and replace the fuse state.
When the fuse is blown, data cannot be received or paper cannot be
fed with the Paper Feed push button.