OLT6 and 1134 Description Installation and Turnup Guide
Page 14 of 50
C.11T-
XO192SR1851M
XFP: 10G, SX, 850NM, MM
100m
2xLC
10G Multimode XFP
C.11T-
XO192IR21550
10GBASE-ER/OC-192 IR-2
Multi-rate 40km Industrial Temp
XFP
40km
2xLC
10G 40km XFP
81.11T-XFPGPON-IT
Tellabs GPON Laser
20km
1xSC
UPC(blue)
2.5/1.25G Bidi
GPON Laser
81.11T-XFPXGSPON
Tellabs XGS-PON Laser
20km
1xSC
UPC(blue)
10G/10G Bidi XGS-
PON Laser
Power Requirements
The 1134/OLT6 has the following AC power requirements when powered by AC:
AC Power Specifications
Value
Comments
AC Input Voltage
100-240VAC
AC Input Line Frequency
50-60Hz (nominal)
AC Current Rating
5A@100VAC,
2.5A@240VAC
Max AC Input Power
600 W
The 1134/OLT6 has the following DC power requirements when powered by DC:
DC Power Specifications
Value
Comment
DC Input Voltage
-42.5 to -56VDC
DC Current Rating
14A @ 42.5VDC
DC Power
600W
Note: This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
The following table lists the power draw per installed card type.