12
FURTHER IMPORTANT SETTINGS IN THE PROGRAMMING
SOFTWARE:
Administrator e-mail address:
For receiving and initiating firmware updates remotely, enter your e-mail in the
Administrator’s e-mail address
field in the
General
device settings
menu of
the programming software.
SMS forwarding:
The device can forward incoming SMS messages to the configured phone
number. For this, configure the phone number in the
SMS forwarding phone
number
field
.
The phone number of the Gate Control PRO:
The mobile app can control your gate via phone call when a mobile Internet error
occurs and therefore it fails to control the gate through the Internet.
For this, configure the phone number of the SIM card installed in the
Gate Control PRO
device under the
General
device settings menu, in the
Device phone number
field found in the
SIM settings
section.
Attention! If you do not set the phone number of the SIM card as described
above, the mobile app will not be able to control the gate via phone call
when a mobile Internet error occurs!
Push messages on errors:
We recommend that you enable
Technical error
and
Gate position limit error
notifications if an error output from your gate automation and/or a gate position
limit switch is connected to the device.
- Select the
Mobile devices
menu in the programming software and read the
users from the device using the
Read users
button.
- Select the mobile device to which error notifications should be sent, and click
on the
Edit
button
- Enable the
Technical error
and
Gate position limit error
options, click on
the
OK
button, and then write the changes into the device using the
Write users
button.