7.7 Adjusting the cleaver's cutting blade height.
By means of a flat screwdriver, work on screw no . 2 (shown
in the previous image) . Turning the screw to the left will
lower the blade . Turning the screw to the right will raise the
blade .
Upon a blade replacement or a position modification, you
may need to readjust its height . Bear in mind that an exces-
sive blade's height may produce splintering or prevent the
cut .
7.8 Replacing the cleaver's cutting blade.
After 16,000 cuts, you may have to replace the cutting
blade . To do this, proceed as follows:
1
Loosen screws 1 and 2 using an Allen wrench . Next, re-
move lateral protection 3 .
2
Remove screws 4 and 5 and extract the blade container .
3
Replace the cutting blade and re-assemble, following
the steps described above in reverse order .
7.9 Stripper
You should occasionally lubricate the stripper's axis to
allow a smooth sliding between both cutting areas . Once
lubricated, remove the excess oil and leave the tool dry .
The stripper has four working zones, as described below:
Position
Description
4
Designed for cutting through 900/250
or 125-micron fibres .
3
Designed to remove the protection
layer between 3 and 1 .6mm, reaching
900 microns .
2
Designed to remove the protection
layer on 900 microns, reaching 250
microns .
1
Designed to remove the protection
layer on 250 microns, reaching 125
microns .
All positions are factory pre-set for a precise operation; the-
refore, any problems you may find with the stripping mean
the stripper is worn out and you should replace it . Remem-
ber that for a correct stripping, the tool should be tilted
45% in relation to the fibre .
7.10 Battery
The equipment comes with an 11 .1V, 7,800 mAh battery from factory .
7.10.1 Battery extraction
To remove the battery, push the side button shown on the image .
Note:
The battery should only be replaced with a battery of the
same type or equivalent . It should not be exposed to excessive
heat, such as heat from the sun, fire or similar .
Recycling:
Prior to depositing the appliance at the collection
facility, the user should remove the battery and deposit it in the
specific collection facility for this kind of waste .