DiSEqC parameter (Sat A, Sat B, Sat C, Sat
D).
-
Positioner (only satellite band): makes it
possible to control the DiSEqC motors
used to move mobile parabolic antennas.
This function is available in satellite mode
and when the equipment is powering the
LNB.
Halt: This command stops the motor
movement.
East: Allows to move the motor in the
EAST direction. Each click corresponds to
one step in the movement of the motor
(pitch motors). By holding the key down,
successive movement sequences will be
executed until the key is released.
West: Motor movement in the WEST
direction. Each click corresponds to
one step in the movement of the motor
(pitch motors). By holding the key down,
successive movement sequences will be
executed until the key is released.
Store: 8 storage positions are available
to store at up to 8 antenna positions . This
command allows one of 8 positions to be
chosen where the current position of the
antenna will be stored.
Goto: recovers one of the 8 positions
for the antenna that has been previously
stored
-
SCR (only satellite band): Selects the SCR
parameters (multiswitch, standard and
slots) When a slot is enabled (for example
slot 3, freq. 1210MHz), the meter will tune
into the slot frequency (1210MHz) and
will set the slot with the meter parameters:
frequency, band (powering), and DiSEqC.
In addition, a SCR icon will be shown in the
bar at the top (SCR3) to indicate that the
slot is enabled. While the slot is enabled,
all the setting changes of the meter, will
be applied to the currently slot (SCR3).
-
CTB (only analog channels): Turns ON/OFF
the CTB measuremnt. If you select CTB ON,
a popup window will be displayed asking
you to turn the signal off. CTB can only be
made with the service disabled, because it
is a measurement made in the frequency
of the video carrier of the TV signal. Turn
the signal ON again to measure CTB and
all other measurements properly.
-
CSO Offsets (only analog channels): The
CSO measure is carried out in different
frequencies (at different distances from the
video carrier) within the selected channel.
Using this menu you can select the offset
where you want to measure the CSO, and
you can save up to 6 offset values, that can
be the default values or user-selected ones.
6.4.5.- Spectrum (RF Input)
This feature shows the spectrum of the signal.
6.4.5.1.-Main window
Power or C/N
measurement.
Tap to change
Spectrum
parameters
Swipe to tune next/previous channel
Drag to tune any channel
Spread/Pinch to change span
Tap to enable/disable marks
Содержание 596101
Страница 1: ...Multi touch Meter Analyser EN Refs 596101 596111 User manual w w w t e l e v e s c o m ...
Страница 2: ......
Страница 65: ...596101_596111_1 32_EN ...