Preparations

NB! Before starting the installation

please read the instruction carefully

When deciding on the best position for the control keep the
control lever movements in mind. Ensure full throttle
movement without obstruction at position chosen before
the hole is cut.
Also check that space required for installation is sufficient.
Installed from the outside the mechanism, seen in fig. 1 &
2, requires a distance of min. 200 mm from the hull to the
inner wall (see fig. 10 & 11). If installed from the inside a
distance of 100 mm is enough.

The mechanism with attaching plate (fig. 3) needs the least
space (appr. 100 mm) when installed from the outside.
The wall or mounting plate must not be thicker than 12
mm.

Fig. 1 & 2

B mechanism

A

Alternative gear cable holders

B

Gear lever

C

Gear cable connection for ± 38 mm travel

D

Gear cable connection for ± 31 mm travel

E

Adjustable brake

F

Neutral position knob

G

Throttle cable holder

H

Throttle lever

J

Screw

K

Washer

L

Attachment holes for neutral safety switch

Fig. 3 shows the mechanism with attachment plate. This
mechanism is used for controls with trim switch function.

2 (16)

Содержание B700SS

Страница 1: ...marine engine controls for side mounting Installer These instructions contain important safety information and must be forwarded to the boat owner...

Страница 2: ...all see fig 10 11 If installed from the inside a distance of 100 mm is enough The mechanism with attaching plate fig 3 needs the least space appr 100 mm when installed from the outside The wall or mou...

Страница 3: ...er groove B fig 5 The mechanism has a two sided gear arm suitable for pulling as well as pushing gear function without prior modification The gear cable should be connected to the side of the lever wh...

Страница 4: ...nism Thread the pivot A fig 8 on to the rod until 4 mm of the rod protrudes see fig 8 Secure the pivot by tightening the nut B fig 8 Connect the pivot to the throttle lever E fig 7 and secure with the...

Страница 5: ...an be moved without noticable resistance or a spongy feeling Shift cable The shifting cable is secured to the mechanism and can therefore be clamped to a bulkhead adjacent to the mechanism Guide the m...

Страница 6: ...ure the lever is securely attached to the shaft Don t tighten too hard just attach the screw securely Check the lever travel Move the lever to engaged gear position Push the neutral position button B...

Страница 7: ...cidental starting with gear engaged NB The switch A fig 20 must be mounted with the electrical plugs B fig 20 turned away from the gear cable DS unit Dual Station unit In a boat with two manoeuvering...

Страница 8: ...003122PO6 Distributor 640 North Lewis Road Limerick PA 19468 USA 610 495 7011 www teleflexmarine com...

Страница 9: ...Sidomonterade motorreglage f r marinmotorer Till installat ren Denna instruktion inneh ller viktig s kerhets information och m ste medf lja b ten...

Страница 10: ...200 mm fr n skrovet till skottet se fig 10 11 Om installationen g rs fr n insidan r cker det med 100 mm avst nd Fig 1 2 B mekanism A Alternativa h llare f r v xelkablar B V xelarm C V xelkabelanslutni...

Страница 11: ...ra OBS Vid tryckande gas m ste rullen A fig 5 l pa i inre sp ret Mekanismen har en genomg ende v xelarm passande f r dragande s v l som tryckande v xelfunktion utan f reg ende modifiering V xelkabeln...

Страница 12: ...t S kra nippeln genom att draga t muttern B fig 8 Anslut nippeln till gasarmen E fig 7 och s kra med saxpinnen F fig 7 OBS Anv nd inte frikopplingsknappen f rr n reglaget r monterat och kablarna anslu...

Страница 13: ...spaken r ras relativt l tt utan motst nd eller fj dring V xelkabeln V xelkabelns h lje r f st i mekanismen och kan d rf r klamras med l mpliga mellanrum direkt efter reglaget Montering fr n insidan M...

Страница 14: ...ter s kert Drag ej s h rt att axeln deformeras Kontrollera att spaken g r fram och back F r spaken till ett v xell ge Tryck neutrall gesknappen B fig 17 18 p plats Anslut kablarna till gas och v xelar...

Страница 15: ...neutrall ges brytare f r att motverka oavsiktlig start med v xeln i OBS Brytaren A fig 20 m ste installeras s att kontaktstiften B fig 20 r v nda fr n v xelkabeln DS enhet I b tar med tv man verplatse...

Страница 16: ...003122PO6 terf rs ljare 640 North Lewis Road Limerick PA 19468 USA 610 495 7011 www teleflexmarine com...

Страница 17: ......

Отзывы: