May
2015
WorkHorse H-ADCP Operation Manual
Page 64
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Installing Feature Upgrades
The feature upgrade installation program is used to install Waves capabilities in an H-ADCP.
The upgrade file is specific to the unit for which it was ordered. DO NOT attempt to install this
feature for any other unit.
Many feature upgrades require the latest firmware version to be installed in your H-ADCP. If
you need to update the firmware, do this before installing the feature upgrade (see
To install a feature upgrade:
1. Set up the H-ADCP as shown in
2. Start the program Activate_HA_xxxx.exe (where xxxx is the H-ADCP’s serial number).
3. The installation program will start (see Figure 25). The program is encoded with the H-ADCP’s
serial number and the requested feature upgrade.
Figure 25.
Installing Feature Upgrades
4. To select the port settings, select the I would like to specify the port setting box and click
Next.
5. Select the Serial Port and Baud Rate.
6. Click Next to install the feature upgrade.
7. Click the Finish button to exit the program.
8. Start BBTalk and use the
to verify the feature upgrade has been installed.