May
2015
WorkHorse H-ADCP Operation Manual
Page 226
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Table 46:
DVL Output Data Format (PD3) Details
Hex Digit
Binary Byte Field
Description
81,82
41
Sensor/Other Data † Output if Bit #7 of “Data to Follow” byte is set. These fields contain the Sensor/Other
data.
Bit #
0 = Time
1 = Heading
2 = Pitch
3 = Roll
4 = Temperature
5 = Active Built-In-Test
83-90
42,43
Time: HH,MM
‡ Sensor/Other Data Bit #0: These fields contains the time of the ping in Hours, Minutes
Seconds, Hundredths of seconds respectively.
44,45
Time: SS,HH
91-94
46,47
Heading
‡ Sensor/Other Data Bit #1: this field contains the Heading in hundredths of degrees.
95-98
48,49
Pitch
‡ Sensor/Other Data Bit #2: this field contains the Pitch in hundredths of degrees.
99-102
50,51
Roll
‡ Sensor/Other Data Bit #3: this field contains the Roll in hundredths of degrees.
103-106
52,53
Temp
‡ Sensor/Other Data Bit #4: this field contains the Temperature in hundredths of degrees.
107-110
54,55
BIT results
‡ Sensor/Other Data Bit #5: this field contains the Built-In-Test results. Each bit specifies
the result of built-in-test during an ensemble. If the bit is set, the test failed.
BYTE 54 BYTE 55 (BYTE 55 RESERVED FOR FUTURE USE)
1xxxxxxx xxxxxxxx = RESERVED
x1xxxxxx xxxxxxxx = RESERVED
xx1xxxxx xxxxxxxx = RESERVED
xxx1xxxx xxxxxxxx = DEMOD 1 ERROR
xxxx1xxx xxxxxxxx = DEMOD 0 ERROR
xxxxx1xx xxxxxxxx = RESERVED
xxxxxx1x xxxxxxxx = DSP ERROR
xxxxxxx1 xxxxxxxx = RESERVED
111-114
56,57
Checksum
This is the 16-bit checksum of all the preceding binary bytes.
† This block of data is only output if the bit is set in the Data to Follow byte.