2.4 CH1 / CH2 Series Mode
In series mode, CH1 and CH2 are linked internally into one channel which is
controlled by CH1, and the output voltage value is twice that of a single channel.
Output rating
0~64V / 0~3.2A
Operation
:
1. Press the “Ser” button to start the Series mode. The indicator light turns on
and the logo “
”
displays at the top of the screen.
2. Connect the load to the positive terminal of CH2 and the negative terminal of
CH1.
3. Set voltage and current values:
a) Press the “1” button to select the channel 1
b) Use the direction buttons to move the cursor to the desired parameter
(voltage, current).
c) Press “Fine” to select the digit position and then turn the multi-function
knob to change the corresponding parameter value.
4. Press the “on/off” button corresponding to CH1 to turn on the output.
Note:
You can identify if the PSU is in “CC” or ”CV” mode by referring to the
indicator light of CH1 / CH2. (red indicates CV, yellow indicates CC).
Quick Start 15
Содержание T3PS3000
Страница 1: ...T3PS3000 Programmable DC Power Supply Quick Start Guide Version 1 3 September 2018 ...
Страница 41: ......