2.2 CH1 / CH2 Independent Output Mode
When CH1 and CH2 are working in independent mode, they each output their
set voltages and currents on their respective output terminals as shown below.
They are isolated from ground.
Output rating: 0~32V / 0~3.2A per channel for channels 1 and 2.
Operation
1. Make sure that parallel / series mode is off.
2. Connect the load to the positive and negative terminals of CH1 or CH2.
3. Set voltage and current value of CH1or CH2:
a) Press “1”/”2” button to select the wanted channel
b) Move the cursor through direction button to select the wanted parameter
(voltage, current).
c) Press “Fine” to select the digit position and then adjust the
multi-function knob to change the corresponding parameter.
4. Turn on the output: Press the “on/off” button to turn on the output, the
corresponding indicator light will illuminate immediately and “CC” or “CV” is
showed on the channel interface.
Quick Start 13