To Test Continuity
Continuity test uses the double leads method to measure the resistance of the
measured circuit via the 0.5mA current. When the measured resistance in circuit
is lower than the selected one, it is considered being connected with the
instrument. The method to test Continuity will be introduced in detail in the
following steps.
Operating Steps:
1. Press
on the front panel to enter the Continuity test interface, as
displayed in diagram 2- 23.
Diagram 2- 23 Continuity Measurement Interface
2. Connect the red lead to the terminal Input-HI and the black lead to terminal
Input-LO as displayed in diagram 2- 24.
Diagram 2- 24 Sketch Map for Testing Continuity