SeaBat UI - User Manual
Operation
39
4.8.1 Raw data Record Selection
Figure 4-47
Record selection
In the record selection the operator can select or unselect by ticking or
unticking the checkbox(es) which data is recorded. Next to the standard
data records extra data records can be recorded.
The standard data records are:
7000
– Ping settings
7004
– Beam geometry
7006
– Bathymetry (legacy)
7011
– Compressed image data
7017
– Bathymetry (for UI display)
7027
– Bathymetry (RAW)
7503
– Sonar settings
The extra records are:
Snippets
:
7028
– Snippets data
Side scan
:
7007
– Backscatter data
Sensor data
(motion, position, heading, etc.):
1003
– Position
1012
– Attitude (Roll, Pitch and Heave)
1013
– Heading
7610
– Sound Velocity
Watercolumn
(includes sensor data):
7018
– Full Magnitude & Phase data
Troubleshooting
(includes watercolumn data):
7021
– BITE data
Other
:
All other available records
When the checkbox is ticked the record numbers will be
displayed at the bottom of the pane in the info box.
The sensor data can only be recorded when these sensors are interfaced
with the sonar system. This can be done in the IO Module. An alternative
is that the position, attitude and heading are send by PDS2000 to the IO
Module. Then only the external clock with 1PPS and the sound velocity
has to be interface in the IO Module.