Installation, Outdoor HPO PowerMAX System
215861 REV C
25
2.1.9 Install Outdoor Controllers
The two (2) Outdoor SSPA Controllers were shipped on a bracket connecting the two
side-by-side, with mounting brackets on the outside edges. If the system includes the
Ethernet option, the Ethernet switch is mounted to the back side of the Outdoor SSPA
Controller assembly.
Secure the mounting brackets to the RF Input side of the uni-strut frame as shown in
Figure 2-23
. The hardware used to attach the supports was shipped in place on
the controller supports. Position the boxes so that the top of each controller is flush
with the top cover of each system frame.
Connect the green/yellow striped ground wire to the ground terminal on the controllers.
Note
: The system RF Distribution Box provides power to the Ether-
net Switch over the Auxiliary Power Cable. See
Section 2.1.10.4
.
On the optional Ethernet switch, the M12 D-coded, 4-pin (F) connectors were shipped
with IP67 caps installed to protect from dust and moisture ingress. The caps will need
to be removed before connecting cables to the COMs port. All unused M12 connectors
should remain capped.
Figure 2-23: Install Outdoor Controllers