Frontline Harmony Hardware & Software User Manual
41
LL/DDI/ADV/BV-34-C
Tests that an advertiser IUT can report the TX Power in advertisements with
RF path compensation using correct payload fields timing and channel
sequence for the maximum time allowed
LL/DDI/ADV/BV-35-C
Tests that an advertiser IUT can support multiple advertising sets with the
correct payload fields timing and channel sequence for the maximum time
allowed. Advertisements with the minimum data required to be supported
are tested
LL/DDI/ADV/BV-39-C
Connectionless CTE Advertising – Maintain CTE Configuration
LL/DDI/ADV/BV-43-C
Periodic Advertising validating SyncInfo fields
LL/DDI/ADV/BV-45-C
Tests that an advertiser IUT sends scannable ADV_EXT_IND PDUs with the
AuxPtr field referring to a valid AUX_ADV_IND PDU on the secondary
advertising channel with the correct payload fields, timing, and channel
sequence for the maximum time allowed. Tests that an advertiser IUT
responds to a scan request on the secondary channel and continues
advertising after the response. Scan response data chaining is tested.
Undirected and Directed events are tested.
LL/DDI/ADV/BV-47-C
Tests that an advertiser IUT using LE 1M PHY sends non-connectable
ADV_EXT_IND PDUs with the AuxPtr field referring to a valid AUX_ADV_IND
PDU on the secondary advertising channel with the correct payload fields,
timing, and channel sequence for the maximum time allowed.
Advertisements with and without data, along with chaining, are tested.
Undirected and Directed events are tested.
LL/DDI/ADV/BV-48-C
Tests that an advertiser IUT using LE Coded PHY sends non-connectable
ADV_EXT_IND PDUs with the AuxPtr field referring to a valid AUX_ADV_IND
PDU on the secondary advertising channel with the correct payload fields,
timing, and channel sequence for the maximum time allowed.
Advertisements with and without data, along with chaining, are tested.
Undirected and Directed events are tested.
LL/DDI/ADV/BV-49-C
Tests that an advertiser IUT using LE 2M PHY sends non-connectable
ADV_EXT_IND PDUs with the AuxPtr field referring to a valid AUX_ADV_IND
PDU on the secondary advertising channel with the correct payload fields,
timing, and channel sequence for the maximum time allowed.
Advertisements with and without data, along with chaining, are tested.
Undirected and Directed events are tested.
LL/DDI/ADV/BV-50-C
Extended Advertising, Legacy PDUs, Undirected, CSA #2
LL/DDI/ADV/BV-51-C
Extended Advertising, Scannable – without ADI – LE 2M PHY
LL/DDI/ADV/BV-52-C
Extended Advertising, Scannable – with ADI – LE 2M PHY
LL/DDI/ADV/BV-53-C
Extended Advertising, Scannable – without ADI – LE Coded PHY
LL/DDI/ADV/BV-54-C
Extended Advertising, Scannable – with ADI – LE Coded PHY
LL/DDI/ADV/BV-55-C
Extended Advertising, Periodic Advertising – LE 2M PHY
LL/DDI/ADV/BV-56-C
Extended Advertising, Periodic Advertising – LE Coded PHY
LL/DDI/SCN/BI-01-C
Tests that a scanner IUT ignores advertising indication packets with invalid
CRC's
LL/DDI/SCN/BI-02-C
Tests that a scanner IUT ignores data in advertising packets with invalid
checksums
Содержание FrontLine Harmony
Страница 1: ...Harmony Test System User Manual...
Страница 7: ...Frontline Harmony Hardware Software User Manual 7 Figure 1 1 Installed Applications Detected...
Страница 25: ...Frontline Harmony Hardware Software User Manual 25 Figure 3 5 IUT Information...
Страница 55: ...Frontline Harmony Hardware Software User Manual 55 Figure 5 4 Testing Summary...