LL/DDI/SCN/BV-34-C
Tests that a scanner IUT can synchronize to periodic advertising events
using both periodic sync establishment filter policy settings, and ignoring
the scanner filter policy
LL/DDI/SCN/BV-36-C
Connectionless CTE Scanning, CTE Type Change
LL/DDI/SCN/BV-37-C
Tests that synchronization will fail on the IUT when an AUX_SYNC_IND PDU
is not received within 6 periodic advertising events after the first advertising
event is sent
LL/DDI/SCN/BV-38-C
Extended Scanning, Periodic Advertising Reception, Reporting Initially
Disabled – LE 1M PHY
LL/DDI/SCN/BV-42-C
Extended Scanning, Passive – LE 2M PHY
LL/DDI/SCN/BV-43-C
Extended Scanning, Passive – LE Coded PHY
LL/DDI/SCN/BV-44-C
Extended Scanning, Active – LE 2M Phy, Core 5.0
LL/DDI/SCN/BV-45-C
Extended Scanning, Active – LE Coded PHY, Core 5.0
LL/DDI/SCN/BV-46-C
Extended Scanning, Periodic Advertising Reception – LE 2M PHY
LL/DDI/SCN/BV-47-C
Extended Scanning, Periodic Advertising Reception – LE Coded PHY
LL/DDI/SCN/BV-60-C
Extended Scanning, Periodic Advertising Reception, Reporting Initially
Disabled – LE 2M PHY
LL/DDI/SCN/BV-61-C
Extended Scanning, Periodic Advertising Reception, Reporting Initially
Disabled – LE Coded PHY
LL/DDI/SCN/BV-62-C
Extended Scanning, Multiple Sets, Active, Multiple PHYs (All Supported
PHYs), Core 5.1
LL/DDI/SCN/BV-63-C
Privacy - Extended Scanning, Active, Core 5.1
LL/DDI/SCN/BV-64-C
Extended Scanning, Active – LE 1M PHY, Core 5.1
LL/DDI/SCN/BV-65-C
Extended Scanning, Active – LE 2M Phy, Core 5.1
LL/DDI/SCN/BV-66-C
Extended Scanning, Active – LE Coded PHY, Core 5.1
LL/DFL/MAS/BV-01
Test that a master IUT correctly transmits packets with fragmented L2CAP
headers.
LL/DFL/MAS/BV-02
Test that a master IUT correctly receives packets with fragmented L2CAP
headers.
LL/DFL/SLA/BV-01
Test that a slave IUT correctly transmits packets with fragmented L2CAP
headers.
LL/DFL/SLA/BV-02
Test that a slave IUT correctly receives packets with fragmented L2CAP
headers.
LL/ENC/ADV/BI-01-C
Scan Request Invalid Address
LL/ENC/ADV/BI-02-C
Master Packets Invalid Address
LL/ENC/INI/BI-01-C
Slave Packets Invalid Address
LL/ENC/MAS/BI-01-C
Tests that a master IUT ignores packets not belonging to the connection
transmitted using a different access address
LL/ENC/SCN/BI-01-C
Passive Scanning Invalid Address
LL/ENC/SCN/BI-02-C
Active Scanning Invalid Address
LL/ENC/SLA/BI-01-C
Tests that a slave IUT ignores a packet starting an event belonging to a
different connection
LL/FRH/ADV/BV-01-C
ADVERTISING/SLAVE - Accepting Connections With Hop Lengths
LL/FRH/MAS/BV-01-C
MASTER - Requesting Channel Map Update
Содержание FrontLine Harmony
Страница 1: ...Harmony Test System User Manual...
Страница 7: ...Frontline Harmony Hardware Software User Manual 7 Figure 1 1 Installed Applications Detected...
Страница 25: ...Frontline Harmony Hardware Software User Manual 25 Figure 3 5 IUT Information...
Страница 55: ...Frontline Harmony Hardware Software User Manual 55 Figure 5 4 Testing Summary...