Frontline Harmony Hardware & Software User Manual
37
LL/CON/SLA/BV-54-C
Test that a slave IUT is able to receive data from a master device when the
master is transitioning between 125kbit and 500kbit coded rates. Confirm
that IUT responds within the allowed T_IFS times for each packet at either
coded rate
LL/CON/SLA/BV-55-C
Test that a slave IUT follows all packet time restrictions both during and
after PHY change when it initiates the PHY Update Procedure
LL/CON/SLA/BV-56-C
Test that a slave IUT follows all packet time restrictions both during and
after PHY change when it responds to a PHY Update Procedure from a
master device
LL/CON/SLA/BV-57-C
Test that a slave IUT still transmits data even when the TxTime and/or
RxTime values for LE Coded PHY suggest a smaller possible data length than
the minimum length data PDU (27 octets)
LL/CON/SLA/BV-58-C
Test that a slave IUT follows all packet time restrictions when a PHY Update
Procedure is initiated but no PHY change occurs
LL/CON/SLA/BV-59-C
Test that a slave IUT follows all packet time restrictions both during and
after PHY change when it responds to a PHY Update Procedure from a
master device but no PHY change occurs
LL/CON/SLA/BV-60-C
Constant Tone Extension Request Procedure, IUT Initiated, AoA – LE 1M
PHY
LL/CON/SLA/BV-61-C
Constant Tone Extension Request Procedure, IUT Initiated, Periodic
LL/CON/SLA/BV-62-C
Constant Tone Extension Request Procedure, IUT Initiated, Responses
Disabled
LL/CON/SLA/BV-63-C
Verifies that the IUT correctly handles the case where the remote does not
support the Connection CTE Response feature.
LL/CON/SLA/BV-64-C
Constant Tone Extension Request Procedure, IUT Initiated, Timeout
LL/CON/SLA/BV-65-C
Constant Tone Extension Request Procedure, IUT Responding, AoA
LL/CON/SLA/BV-66-C
Constant Tone Extension Request Procedure, IUT Responding, Responses
Disabled
LL/CON/SLA/BV-67-C
Constant Tone Extension Request Procedure, IUT Initiated, AoD – LE 1M
PHY
LL/CON/SLA/BV-68-C
Constant Tone Extension Request Procedure, IUT Responding, AoD
LL/CON/SLA/BV-69-C
Unrequested Constant Tone Extension, IUT Receiving, AoA – LE 1M PHY
LL/CON/SLA/BV-70-C
Unrequested Constant Tone Extension, IUT Receiving, AoD – LE 1M PHY
LL/CON/SLA/BV-71-C
Constant Tone Extension Request Procedure, IUT Initiated, AoA, Encrypted
Connection – LE 1M PHY
LL/CON/SLA/BV-72-C
Constant Tone Extension Request Procedure, IUT Responding, AoA,
Encrypted Connection
LL/CON/SLA/BV-73-C
Constant Tone Extension Request Procedure, IUT Initiated, AoD, Encrypted
Connection – LE 1M PHY
LL/CON/SLA/BV-74-C
Constant Tone Extension Request Procedure, IUT Responding, AoD,
Encrypted Connection
LL/CON/SLA/BV-75-C
Constant Tone Extension Request Procedure, IUT Initiated, AoA, Incorrect
CRC – LE 1M PHY
LL/CON/SLA/BV-77-C
Verify that the IUT as Slave correctly handles reception of an
LL_LENGTH_REQ PDU on the LE 1M PHY
Содержание FrontLine Harmony
Страница 1: ...Harmony Test System User Manual...
Страница 7: ...Frontline Harmony Hardware Software User Manual 7 Figure 1 1 Installed Applications Detected...
Страница 25: ...Frontline Harmony Hardware Software User Manual 25 Figure 3 5 IUT Information...
Страница 55: ...Frontline Harmony Hardware Software User Manual 55 Figure 5 4 Testing Summary...