40
TMP800 Installation Guide
6.6
General Debugging Tips
To solve problems quickly and efficiently, logs are the primary source of information that aid
TelcoBridges support in determining the events that led to a reported problem.
Network configuration is important because it tells us:
•
If the host applications (or TB applications) are running on a host having more than 2 Ethernet
interfaces or having more than 1 IP address on the same Ethernet interface. The
TBX_GW_ADDRESS_0 and TBX_GW_ADDRESS_1 must be set to match with the subnet used
for ETH0 and ETH1 of the TB hardware products.
If you need run separate systems running on the same network, the communication port system_ID
used on the Tmedia units and the application can be changed.
To set the system_ID on the Tmedia units, do the following:
•
Telnet to the hardware and do set_boot command. Change the system_ID through the gateway
port parameter.
The default value is 12358.
To set the system_ID for the pre-compiled TB applications:
•
Set the system_ID through TBX_GW_PORT in the config.txt file of the TB applications. If zero is
used, the application will look for the environment variable TBX_GW_PORT for the System_ID
value. If the variable is missing, the default System_ID value 12358 will be used.
To set the system_ID for user application:
•
Set the un32GwPort parameter in the TBX library parameters. If zero is used, the application will
look for the environment variable TBX_GW_PORT for the System_ID value. If the variable is
missing, the default System_ID value 12358 will be used.
Note
system_ID is also referred to as tbx_gw_port and gateway port.