GW-482S INSTALL ATION GUID E
8
MN100143 Rev B
Power Cable Connection
To insert the Power Cable into the Cabinet:
1.
The power cable is enclosed in a conduit. Use the supplied flange and a Neoprene gasket
with the appropriate hole size (according to the conduit’s diameter), as follows:
•
Fit the Neoprene gasket over the hole beneath the grounding terminal inside the cabinet.
•
Place the flange over the gasket and secure firmly with four screws. Use the supplied
screws, washers, spring-washers and nuts.
Figure 10: Flange and Gasket for Power Cable Conduit
2.
Push the end of the power-cable’s conduit firmly through the gasket’s aperture.
Figure 11: Flange and Gasket, Outer View
3.
Roll and fit the cable slack into the cable holders on the cabinet walls.
4.
For GW-482S-LV-X connect the BNC connector to the Con 5 connector on the Main
Board. Skip sections on “ Connecting the AC Power Cable” and “ Installing the Battery”
and go directly to Connecting Ethernet and Phone Cables.
Do NOT plug the external power supply into the AC pow er at this time!