4.3 FASTENING the pressure reducer
The generating set comes standard with
the suit-
able pressure reducer (Fig. 5 Ref. 4) already set,
and 1 metre long gas hose (Fig. 5 Ref. 2) which
is already connected to both the generating set
(Fig. 5 Ref. 1) and the pressure reducer.
The reducer should be fastened using the suit-
able holes located on the 3 wings (Fig. 7 Ref.1).
Remember that the pres-
sure reducer must NOT be installed in the
body interior. Moreover, it should be located
in a well-ventilated area.
No pressure reducing device should be placed
between the Telair reducer (Fig. 5 Ref. 4) and the
gas bottle.
The gas hose (Fig. 5 Ref. 5) which directly con-
nects the pressure reducer and the gas bottle
(Fig. 5 Ref. 6) is not supplied.
For this connection, the installer will use a suit-
able type-approved hose which is equipped with
the suitable fittings.
Connections as shown
in Fig. 6 are FORBIDDEN on both the reducer
and the gas bottle.
Fig. 7 shows proper connection, with a suitable
hose on which the fitting (6) is tightened.
Fit the ogive (7), hold the fixed hexagon ring (8)
by means of a wrench and tighten the ring nut
(9).
When using the genera-
tor in cold environments, please remem-
ber that the lower the temperature (down
to a temperature limit of – 15°C), the high-
er the percentage of propane gas which is
recommended
7
6
5
Содержание ENERGY 8012 GAS
Страница 24: ...Energy 8012 G Vers 001 GB 24 DRAWING FOR SPARE PARTS LIST ENERGY 8012 GAS ...
Страница 25: ...Vers 001 Energy 8012 G GB 25 ...
Страница 26: ...Energy 8012 G Vers 001 GB 26 ...
Страница 31: ...Vers 001 Energy 8012 G GB 31 Notes ...
Страница 32: ...Energy 8012 G Vers 001 GB 32 Contro Copertina Telair ...