4.4 Preparing the Wiring connection
Use the suitable key to open the lock and remove
the front door.
Then remove the fastening screw (Fig. 8 Ref. 2)
of the lower surface on both sides.
Take out the lower surface with the engine up to
the retainer (Fig. 8 Ref. 3)
Should you wish to take out the engine holding
surface in full, remove the setscrews (Fig. 8 Ref.
3) too.
The wiring connections
to the generating set must be made by quali-
fied personnel.
4.5 Battery connection
To start up the generating set, you must connect
to the vehicle battery using a sheathed cable (to
determine its cross-section, see Table 1) in com-
pliance with the regulations in force.
For this purpose, the generating set is provided
with two terminals (Fig. 10 Ref. 1) used to con-
nect the positive and the negative poles of the
battery.
Connect the positive pole cable (red cable) to the
terminal which is already provided with a red ca-
ble, and the cable of the negative pole to the
terminal already provided with a black cable. The
cable of the negative pole must be of the same
cross-section as the positive cable and must be
connected to both the negative pole of the bat-
tery and the chassis of the vehicle.
The contact must be good. If necessary, remove
any paint or rust from the contact surface, and
protect the connection with grease.
The start-up battery must have a capacity of at
least
100 A/h.
The soundproofing case is provided with a cable
holder to let the battery connection cables go
through (Fig. 8 Ref. 1).
The cable holder will prevent water from entering
the generating set.
Check the proper posi-
tion of the 12 Vdc current pick-up line care-
fully. A wrong connection could cause irrepa-
rable damage to the generating set or create
dangerous short circuits.
4.6 12 Volt connection
Any use of 12 Vdc is to be drawn from the gen-
erating set battery, via a cable of suitable size.
The cable of the negative pole must be of the
same cross-section as the positive cable.
Even if the generating set
is provided with a power cutout fuse (Fig. 10
Ref. 5) in case of overload or short-circuit, a
suitably calibrated thermal cutout should be
installed inside the switchboard of the vehi-
cle, which disconnects the power line to us-
ers whenever power input exceeds 70 Amp.
TABLE 1
Battery
Connection
Cable
length
< 6 m
> 6 m
Cross
sect. mm
2
25
35
9
8
Содержание ENERGY 8012 GAS
Страница 24: ...Energy 8012 G Vers 001 GB 24 DRAWING FOR SPARE PARTS LIST ENERGY 8012 GAS ...
Страница 25: ...Vers 001 Energy 8012 G GB 25 ...
Страница 26: ...Energy 8012 G Vers 001 GB 26 ...
Страница 31: ...Vers 001 Energy 8012 G GB 31 Notes ...
Страница 32: ...Energy 8012 G Vers 001 GB 32 Contro Copertina Telair ...