Energy 8012 G
Vers. 001
GB
8
Do not turn the package
upside down. The right position is the one
shown by the symbol printed on the package
(
).
3.2 Weight
Total weight including packing:
ENERGY 8012 GAS: 52 kg
3.3 Handling
The generating sets, complete with their packag-
ing, can be moved using common lifting and
transport vehicles.
The boxes are provided with spacers in order to
allow for the introduction of transpallet forks.
During lifting and trans-
port, comply with accident prevention and
safety regulations. Use lifting and transport
equipment with a capacity greater than the
load to be lifted.
4 INSTALLATION
4.1 PRELIMINARY NFORMATION
Before installing the condi-
tioner, it is absolutely necessary to read
these instructions, in order not to make any
mistakes during installation.
The generator must be in-
stalled so as to prevent water seeping directly
into the alternator through the inlet holes; it
must therefore be protected.
Improper installation of the generating sets
can cause irreparable damage to the equip-
ment and compromise the safety of the instal-
lation engineer.
Should the generating sets be installed in a man-
ner which does not comply with the instructions
in this manual, the Manufacturer shall be held
harmless for malfunctions or for the safety of the
generating set, under D.M. 89/392/EEC. Fur-
thermore, he shall be held harmless for any
damage or injury to people or things.
Installation must be per-
formed by qualified and properly trained per-
sonnel only.
4.2 FASTENING the generating set
The ENERGY 8012 GAS generating sets are
provided with anchoring brackets with extra vi-
bration dampers (Fig. 4, Ref. 1). The brackets al-
low for hanging assembly.
This kind of assembly provides the following ad-
vantages: less room taken up, quick installation,
easy access for routine and unscheduled main-
tenance.
Make sure that there is enough room around the
hood of the generating set to allow cooling air to
pass; leave at least 20 mm free room between
the hood and the surrounding parts.
Should the generating set be behind a wheel of
the vehicle, care should be taken to prevent
water from being sprayed into the generating
set by the wheel when raining.
Make sure that the engine
frame can be taken out when the door is open
(Fig. 9).
4
Содержание ENERGY 8012 GAS
Страница 24: ...Energy 8012 G Vers 001 GB 24 DRAWING FOR SPARE PARTS LIST ENERGY 8012 GAS ...
Страница 25: ...Vers 001 Energy 8012 G GB 25 ...
Страница 26: ...Energy 8012 G Vers 001 GB 26 ...
Страница 31: ...Vers 001 Energy 8012 G GB 31 Notes ...
Страница 32: ...Energy 8012 G Vers 001 GB 32 Contro Copertina Telair ...