6
Troubleshooting
6-14
Phaser 540 Color Printer
One dark, horizontal band
appears on the print
approximately 241 mm
(9.5 in) from the leading
edge.
The media “stalled” for a few seconds
in the fuser. The cause:
■
Media is installed wrong side up.
■
Media is curled.
■
The fuser needs to be replaced.
■
The printer needs adjustment.
■
Turn over the media in the media tray.
■
Replace the media.
■
Replace the fuser.
■
Call Service.
Front panel reports:
Transfer Kit:replace
The transfer kit (transfer roller and
waste bin) is worn out.
Replace the transfer kit.
Toner spots appear on the
backside of the media.
The transfer kit is worn out.
Replace the transfer kit.
Light horizontal bands appear
in all colors.
The contact on the transfer roller is not
working properly.
Call Technical Support. See page 6-1.
Troubleshooting and print quality quick reference (cont’d.)
Symptom
Possible Causes
Solution
Print Quality Test Page
Cyan
Magenta
Yellow
Black
Count
Image Unit
1505
Corona
487
Transfer Kit
484
Fuser
0
Print Quality Test Page
Cyan
Magenta
Yellow
Black
Count
Image Unit
1505
Corona
487
Transfer Kit
484
Fuser
0