plitude of 5 cm. This must be repeated for each Signal Gen
erator frequency change.
(4) Check the display flatness over the dispersion window
by tuning the signal across the graticule area (from the
left to right side) with the RF CENTER FREQ control. Signal
amplitude should not change more than ± 1 .5 d B from its
average amplitude, or a total of 3 dB.
NOTE
It is possible that the 5 cm signal reference a m
p litu de established in step ( 3 ) m ay be a minimum
or maximum signal response point through the
dispersion w in d ow . Check fo r and use the a v e r
a g e signal am plitude over the dispersion w in d o w .
Calibration— Type 1L30
TABLE 6 - 4
RF Center Frequency
A p p lied Signal
G en erato r Frequency
1450 M H z - 1550 M Hz (S'cale 1)
1500 MHz
1950 M H z -2050 MHz (Scale 1)
2000 M Hz
2450 M Hz - 2550 M Hz (Scale 2)
2500 MHz
2950 M Hz - 3050 M Hz (Scaie 2 p
3000 MHz
3450 M Hz - 3550 M Hz (Scale 2)
3500 MHz
4200 M Hz - 4300 M Hz (Scale 3)
4500 MHz
4750 M Hz - 4850 M Hz (Scale 4)
4800 MHz
5750 M Hz - 5850 M Hz (Scale 4)
5800 MHz
6750 M Hz - 6850 M Hz (Scale 5)
6800 MHz