Performance Check— Type 1120
POS
IF ATTEN
DISPERSION RANGE
DISPERSION
RESOLUTION
VIDEO FILTER
VERTICAL DISPLAY
RF INPUT
Position the trace to the
bottom line of the
graticule
ALL OFF
kH z/C M
50
Fully clockwise
O ff (Down)
LIN
BANDS 2-5
b. Set the oscilloscope sweep rate to 50 ms/cm.
c. Apply a 200 MHz signal from the Time-Mark Generator
HF SELECTOR OUTPUT connector to the BANDS 2-5 RF
INPUT connector.
d. Adjust the Analyzer G A IN control for a 6 centimeter
signal.
e. Check the display for a signal width of 2 centimeters
at 3 centimeters above the base line. (See Fig. 5-3.)
Fig. 5-3. Typical for Resolution Check (Step 7 ) .
8. IF Attenuator Accuracy Check
a.
Preset the controls of the Spectrum Analyzer as follows:
DISPERSION RANGE
M H z/C M
DISPERSION—
1
COUPLED RESOLUTION
VIDEO FILTER
O ff (Down)
VERTICAL DISPLAY
LIN
RF INPUT
BAND 1
IF ATTEN
All OFF
display is exactly 6 centimeters high. The generator Atten
uator control should read —69 dBm ± 0.1 dBm.
e. Switch the 1 dB IF ATTEN switch to OFF.
f. Check the rest o f the IF ATTEN steps as directed in
Table 5-2.
TABLE 5-2
Spectrum A n a ly z e r
IF ATTEN switch On
RF G e n e ra to r
A tte n u a to r C o n tro l
Setting
2 dB
—68 dBm ± .2 dBm
4
dB
—66 dBm ± .4 dBm
8 dB
—62 dBm ± .8 dBm
16 dB
—54 dBm ± 1 .6 dBm
20 dB
—50 dBm ± 2 .0 dBm
9. IF CENTER FREQ Control Range Check
a.
Preset the controls on the Spectrum Analyzer as follows:
POS
IF CENTER FREQ
FINE IF CENTER FREQ
DISPERSION RANGE
DISPERSION-
COUPLED RESOLUTION
VERTICAL DISPLAY
RF INPUT
Position the trace to the
bottom line of the
graticule
Midrange (000)
Midrange
M H z/C M
10
LOG
BANDS 2-5
b. A pply 100 MHz and 10 MHz markers from the Time-
Mark Generator to the BANDS 2-5 RF INPUT connector.
c. Adjust the G A IN control so that the 10 MHz markers
are visible.
d. The second harmonic of the 100 MHz signal should be
centered on the graticule; if it is off-center, readjust the
front panel IF CENTER FREQ CAL adjustment.
e. Rotate the 10-turn IF CENTER FREQ control to both
ends of its range. The markers must move at least 1 centi
meter (10 MHz) from center in each direction.
f. Change the DISPERSION to 5 MHz/CM.
g. Rotate the 10-turn IF CENTER FREQ control through its
range. The markers must move at least 25 MHz from center
in each direction.
h. Center the 10-turn control and rotate the FINE IF
CENTER FREQ control to the ends of its rotation. The markers
must move at least 1 MHz in each direction.
b. Apply a —70 dBm 200 MHz signal from the Type 608D
RF generator to the BAND 1 RF INPUT connector of the
Spectrum Analyzer.
c. Set the Spectrum Analyzer G A IN control so that the
200 MHz signal is exactly 6 centimeters high.
d. Switch the 1 dB IF ATTEN switch on (up) and adjust the
Attenuator control of the generator so that the 200 MHz
i. Change the DISPERSION to 500 kHz/CM.
j. Rotate the 10-turn IF CENTER FREQ control to the ends
of its rotation. The markers must move at least 2.5 MHz
from center in each direction.
k. Center the 10-turn control and rotate the FINE IF
CENTER FREQ control to both ends o f its rotation. The
markers must move a t least 50 kHz in each direction.
5 -4
Содержание 1L20
Страница 4: ...Type 1L20 Fig 1 1 Type 1L20 Spectrum Analyzer...
Страница 16: ...NOTES...
Страница 18: ...Fig 3 1 Block Diagram of the Type 1L20 N Circuit Description Type 1L20...
Страница 32: ...Maintenance Type 1L20 4 10 Fig 4 6 Phase Lock and Recorder Detector Circuit Boards...
Страница 42: ...Calibration Type 1L20 4B 40 4D 4E 6 2 Fig 6 1 Recommended equipment for calibrating the Type 1L20...
Страница 43: ...Calibration Type 1L20 10 11 12 13 14 15 6 3 Fig 6 2 Recommended Calibration tools and equipment...
Страница 94: ......
Страница 97: ...N0I133S 3H ZHU i...
Страница 98: ...TYPE IL LO SPECTRUM ANALYZER A P H A S E LO C K U S C IR C U IT 2 PHASE LOCK CIRCUIT...
Страница 100: ...T 1 SW EEPER CIRCUITS...
Страница 102: ...N B IFA M PL 70 MHz OSC 6...
Страница 103: ...I o o z o o 5 1166 TYPE IL Z 0 IL 3 0 SPEC TR U M ANALYZER A VARIABLE RESOLUTION CIRCUITS T V A R IA B L E RESOL...
Страница 104: ...5 M H z AM PLIFIE R D E TECTO RS TYPE IL Z O IL 3 0 S P E C T R U M ANALYZER A OUTPUT AMPLIFIER OUTPUT AMPLIFIER...
Страница 105: ...TYPE 1L20 SPECTRUM ANALYZER...
Страница 106: ...FIG 2 REAR CHASSIS TYPE 1L20 SPECTRUM ANALYZER 1 F IG 2...
Страница 107: ...FIG 3 IF CHASSIS T i T L A TYPE 1L20 SPECTRUM ANALYZER F I G 3...
Страница 108: ...FIG 4 LOW PASS FILTER PHASE LOCK ASSEMBLY FIG 4...
Страница 110: ...OPTIONAL ACCESSORIES TYPE 1L20 SPECTRUM ANALYZER...
Страница 112: ...TYPE 1L20 TYPE 1L30 PARTS LIST CORRECTION CHANGE TO R823 30 0181 00 180 a 1W 10 Cl 366...