10. The harness wires going to the alternator all need to be extended as the alternator is
moving to the right side of the engine. Use the provided red to red with white stripe, orange to
pink and black to black, 16 GA wires along with the red 10 GA wire. Cut, solder, and wrap the
extension pieces in, one wire at a time.
11. Remove both of the nuts on the right engine mount bracket and slide the ground strap up
off of the front bolt.
12. Take the alternator mount bracket and slide onto both of the bolts sticking through the
engine mount plate. Re-install the ground strap under the front nut. Use factory nuts to fasten
into place. See previous photo.
June 2021© New Holland G6030/6035 ROPS Cab Installation Manual