24
Er08 Combustion fan encoder.
Occurs if the controller is
unable to obtain rotational
speeds according to the value
defined by it.
Check the plug and connecting
cable on the fan and controller
Possible fan or encoder
malfunction
Reset the error and
restart the boiler, if the
error persists, call a
technician.
Er09 Water pressure sensor
Occurs if the boiler water
pressure drops below 0.4bar
Water pressure dropped below
0.4bar.
Check
the
water
pressure,
identify
possible leaks in the
installation.
Er10 Water pressure sensor
Occurs if the water pressure
exceeds the value of 2.4 bar
Check the auto-fill valve, it
may be blocked.
The installation does not have
an expansion vessel capable
of accumulating the expansion
of water by heating it.
When the water reaches 75ºc,
the pressure must not rise by
more than 0.5 bar.
To check for the lack of
expansion capacity, set
the pressure with the
boiler cold at 1.2 bar,
turn on the boiler and
when it is at 75ºc check
the pressure. If it rose
by more than 0.5bar,
the lack of an additional
expansion
vessel
is
confirmed.
Er11 Internal clock error
Incorrect day and time due to
prolonged absence of power
supply
The
boiler
has
been
disconnected from power for a
long time and the internal
battery has discharged, losing
the programming.
Call a technician.
Er12 Smoke temperature sensor
Misfire
The smoke temperature did
not reach the ignition setpoint
(+/-50ºc) and after this value
it did not rise by another 5ºc.
Lack of pellets in the hopper
Blocked auger
Pellets with high moisture
content
Brazier obstructed
End of life igniter
Check the level of pellets
in the hopper, clean the
burner and check the
resistance against the
burner
Er15 Lack of supply voltage 230V,
A power failure has occurred
Lack of electricity
Check outlet, electrical
panel.
Er16 RS485 communication error
Occurs when communication
between controller and panel
fails
Lack
of
communication
between panel and controller
Check plug or cable.
Reset and reconnect.
Er17 Air flow meter error
Occurs if the chimney is
clogged
Check sensor connections
Check
chimney,
possible
obstruction.
Open ash door or drawer
Er18 Pellet level sensor
It only occurs if the equipment
is equipped with a pellet level
sensor
Pellet level does not cover
sensor
Hopper without pellets
Refill hopper