14
State
Code
State
Code
OFF
-
Operation
-
Verification
Check
Modulation
mod
Ignition-Preheating Phase
on 1
Standby
STBY
Ignition-Pre-Charge Phase
on 2
Safety
SAF
Ignition-Fixed Phase
on 3
Extinction
OFF
Ignition-Variable Phase
on 4
Block
Alt
Stabilization
on 5
Recover the ignition
rec
8.7. Messages
Description of messages
Code
Viewing the status of the temperature probes. The message displayed in the
Check-Up indicates that the temperature reading on one or more probes is equal
to the minimum (0 °C) or maximum value (depends on the probe considered).
Check that the probes are not open (0 °C) or that they are short-circuited
(maximum value of the temperature scale).
probe
Open door. You must close the door!
door
Delay in stopping the equipment. The equipment was turned off when it was on.
Wait for this operation to complete.
OFF DEL
This message notifies you that the planned hours of operation (parameter T67)
are reached. Proceed to cleaning. To clear the warning, access menu 1 and
perform the Cleaning
Reset ( rCLr )
CLr
Periodic cleaning running. Information message that the equipment is
performing periodic cleaning.
PCLr
Supply pellets
rFiL
Open hopper thermostat.
FLAM
Automatic periodic cleaning running
PCLr
- Error codes:
See point 10- Error codes.
8.8. Views.
Display
Un
Description
K100
T. Exhaust
[°C]
Smoke temperature
T. Room
[°C]
Local temperature; visible if A19=1
T. Remote room
[°C]
Remote ambient temperature; visible if remote probe is
configured and P69>0