Teikoku USA | Chempump
Instruction Manual G-Series
37
3 x 2 x 8
A-70037
5
JFK
REVISION DATED 9/92: COMPUTER GENERATED
SERIAL #
04-26-72
GVE(T)
3450
D-38783
(W/INDUCER)
7 1/2"
8"
45%
20%
30%
40%
50%
5 1/2"
6"
6 1/2"
7"
C-39373
7.5K(11.0kw)
10K(15.5kw)
NPSH
IMP. DIA.
wire to water. Numbers beneath model designations indicate full load kilowatt ratings for the referenced motor load lines. When pumping fluids with specific gravities
Curves are based on shop test while handling clean water at 20
o
C and at sea level. Performance guarantees apply at rating point only. Efficiencies shown are overall
M3/H
0
9
18
27
36
45
54
63
72
81
90
99
108
H
E
A
D
(f
t)
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
320
GPM
0
40
80
120
160
200
240
280
320
360
400
440
480
NPS
H
R (
m
tr)
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
45
48
H
E
A
D
(m
tr)
0
6
12
18
24
30
36
42
48
54
60
66
72
78
84
90
96
NPSHR (
ft)
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
15K(20.0kw)
20K(27.0kw)
greater than 1.7, consult your Chempump representative or the factory.
of water. Please note that this is merely a short cut method to estimate the model required. For proper model selection, especially when handling a fluid with a Sp. Gr.
other than 1.0, select pump model (see load line) to handle load equivalent in feet of water. e.g, 40 feet of fluid of Sp. Gr.=1.5 is load equivalent of 60 feet (1.5x40)
DRAWN
REV.
CURVE
DATE
RPM
MODEL
SIZE
IMPELLER
PUMP CASING
Page A-9
Appx. I. Curve - GVE(T) Model