![TECO L510-101-SH1-N Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/teco/l510-101-sh1-n/l510-101-sh1-n_manual_1072466021.webp)
20
Group 08- Drive & Motor Protection
functions
No. Description
Range
Factory
Setting
Note
08-07
Over heat
Protection
(cooling fan
control)
0: Auto (Depends
on temp.)
1: Operate while in
RUN mode
2: Always Run
3: Disabled
1
08-08
AVR
Function
(Auto
Voltage
Regulation)
0: AVR function
enable
1: AVR function
Disable
2: AVR function
disable for stop
3: AVR function
disable for
deceleration
4: AVR function
disable for stop
and deceleration.
5: When
VDC>(360V/740V)
, AVR function
disable for stop
and deceleration.
4
08-09
Input phase
lost
protection
0: Disabled
1: Enabled
0
08-10
PTC
Overheat
Function
0: Disable
1: Decelerate to
stop
2: Coast to stop
3: Continue
running, when
warning level is
reached.
Coast to stop,
when protection
level is reached.
0
08-11
PTC Signal
Smoothing
Time
0.01~10.00 0.2
08-12
PTC
Detection
Time Delay
1~300 60
08-13
PTC
Protection
Level
0.1~10.0 0.7
08-14
PTC
Detection
Level Reset
0.1~10.0 0.3
08-15
PTC
Warning
Level
0.1~10.0 0.5
08-16
Fan Control
Temperatur
e Level
10.0~50.0 50.0
08-17
Over current
protection
level
0.0 ~ 60.0
0.0
Group 08- Drive & Motor Protection
functions
No. Description
Range
Factory
Setting
Note
08-18
Over current
protection
time
0.0 ~ 1500.0
1.0
08-19
Motor
Overload
Protection
Level
0: Motor Overload
Protection Level 0
1: Motor Overload
Protection Level 1
2: Motor Overload
Protection Level 2
0
Group 09- Communication function
setup
No. Description
Range
Factory
Setting
Note
09-00
Assigned
Communicat
ion Station
Number
1 ~ 32
1
*2*3
09-01
Communicat
ion Mode
Select
0: Modbus RTU
code
1: Modbus ASCII
code
2: BACnet
0 *2*3
09-02
Baud Rate
Setting
(bps)
0 :4800
1: 9600
2: 19200
3: 38400
4: Remote Control
is enabled
2
*2*3
◇
09-03
Stop Bit
Selection
0: 1 Stop Bit
1: 2 Stop Bits
0 *2*3
09-04
Parity
Selection
0: Without Parity
1: With Even Parity
2: With Odd Parity
0 *2*3
09-05
Data Format
Selection
0: 8-Bits Data
1: 7-Bits Data
0 *2*3
09-06
Communicat
ion time-out
detection
time
0.0 ~ 25.5
0.0
09-07
Communicat
ion time-out
operation
selection
0: Deceleration to
stop
(00-15:
Deceleration time 1)
1: Coast to stop
2: Deceleration to
stop
(00-17:
Deceleration time 2)
3: continue
operating
0
09-08
Error 6
verification
time.
0 ~ 20
3
09-09
Drive
Transmit
delay Time
(
ms
)
5 ~ 65
5
09-10
BACnet
stations
1~254 1
*2*3
Содержание L510-101-SH1-N
Страница 1: ......
Страница 30: ...2 1 4 5 5 1 5 10 50 1 95 RH 1 10 50 10 40 1 6...
Страница 31: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...
Страница 33: ...5 2 2 2 PNP 200V L510 2P2 SH1 F P L510 2P5 SH1 F P L510 201 SH1 F P L510 202 SH1 F P L510 203 SH1 F P...
Страница 35: ...7 2 2 4 PNP 400V L510 401 SH3 F P L510 402 SH3 F P L510 403 SH3 F P...
Страница 39: ...11 3 3 1 00 01 V F 02 03 04 05 06 07 08 09 10 PID 11 12 13 14 PUMP 1 v07 2 3 4...
Страница 63: ...L510s EMC EMC EMC 2P2 2P5 201 202 203...
Страница 64: ......