49
/
52
CALIBRATION -
SAMPLING ERROR
15
The self-calibration welding was
not carried out or current
measurement errors occurred
during the self-calibration
procedure.
Repeat the self-calibration
procedure. If the error occurs
again, check the electric
connection of the current
transducer.
CALIBRATION NO
CURRENT ERROR
16
This error occurs when the control
unit does not measure the current
during the self-calibration welding
procedure.
Check for continuity of the
secondary circuit. Check the
electric wiring of the current
transducer. Repeat the self
calibration procedure.
CALIBRATION
TE500 IN "NO
WELD"
17
This error occurs when performing
the self-calibration welding
procedure in "NO WELD".
Activate the "WELD" function and
repeat the self-calibration welding
procedure.
THERMOSTAT
ACTIVATED
18
The protection thermostat inside
the welder has been activated.
Check that water is flowing inside
the welder in the necessary
quantity and / or check the working
efficiency of the thermostat.
SOLENOID VALVES
OVERHEATING
19
The short circuit safety device of
the control unit outputs has
tripped.
Check the electric wiring of the
control unit. Check the coil of the
solenoid valve.
ALARM CURRENT
ERROR
20
During the welding process an
error occurred during the current
measurement procedure.
The control unit cannot measure
the welding current properly.
Contact the customer service.
ALARM CURRENT
OVERFLOW
21
A weld with a too-high current
signal has occurred.
Change the programming
parameters of the welding program
or change the ammeter capacity, if
possible.
----STOP----
MAX. SPOTS N.
22
The welds counter has attained the
maximum set value.
Clear the counter, see chapter
"FUNCTION OF THE WELDS
COUNTER"
STOP MINIMUM
CURRENT LIMIT
23
The control unit counts some faulty
spots, the last of which has been
carried out with a current value
lower than the min. set limit.
Clear the error by pressing any
key. See chapter "CURRENT AND
CONDUCTION ANGLE LIMITS"
CURRENT > MAX.
CURRENT
24
The set value in CURRENT 1
parameter is higher than the max.
current value of the welder.
Set the CURRENT 1 parameter to
a lower value than the max.
current value of the welder.
CURRENT LIMITS >
MAX. CURRENT
25
The set value in one of the current
limits (parameters 17-18) is higher
than the max. current value of the
welder.
Set the current limits to a lower
value than the max. current value
of the welder.
MIN. CURRENT >
MAX. CURRENT
26
The set value in MIN. CURR. (17)
is higher than the set value in MAX
CURR (18).
Set the min. current limit to a lower
value than the max. current limit.
DEG MIN > DEG
MAX.
27
The set value in ANGLE MIN (17)
is higher than the set value in
ANGLE MAX. (18)
Set the minimum conduction angle
value to a lower value than the
maximum limit.