CURR MIN / ANGLE MIN (MINIMUM CURRENT LIMIT OR CONDUCTION ANGLE)
The meaning of this parameter depends on the control mode selected in the CONTROL MODE
parameter.
When the control unit is set to current control mode (CONTROL MODE=CUR), this parameter fixes a
minimum current value. For each weld, the TE500 monitors that the welding current supplied by the
welder is higher than the value set at this parameter; if it is lower, an error message will be displayed
(see the relevant paragraph).
When the control unit is set to degree control mode (CONTROL MODE=DEG), this parameter fixes a
minimum conduction angle value. For each weld, the TE500 monitors that the maximum welding
current conduction angle supplied by the welder is higher than the value set at this parameter; if it is
lower, an error message will be displayed (see the relevant paragraph).
If the CONTROL MODE parameter is set to NO (no control on the welding current), the parameter is not
displayed during the programming phase.
CURR MAX. / ANGLE MAX. (MAXIMUM CURRENT LIMIT OR CONDUCTION ANGLE)
This parameter expresses different data according to the control mode selected at the CONTROL
MODE parameter:
When the control unit is set to current control mode (CONTROL MODE=CUR), this parameter fixes a
maximum current value. For each weld, the TE500 monitors that the welding current supplied by the
welder is lower than the value set in this parameter; if it is higher, an error message will be displayed
(see the relevant paragraph).
When the control unit is set to degree control mode (CONTROL MODE=DEG), this parameter fixes a
maximum conduction angle value. For each weld, the TE500 monitors that the maximum welding
current conduction angle supplied by the welder is lower than the value set in this parameter; if it is
higher, an error message will be displayed (see the relevant angle).
If the CONTROL MODE parameter is set to NO (no control on the welding current), the parameter is not
displayed during the programming phase.é