22
/
52
LOCK/END OUT
This parameter indicates, interlock (LOCK) or cycle end (END), the activation time of the corresponding
output.
RECALL 5 FUNCTION
This parameter indicates the function associated to the Recall 5 input.
_ Input for the direct recalling of the work program up to 31 (REC 5).
_ EVEN parity test input for the other recalls.
_ ODD parity test input for the other recalls.
LOW FORCE SQUEEZE
This parameter is activated for welders that envisage the low-pressure squeeze function. Its enabling
adds the Squeeze parameter to the welding program.
FORGE FUNCTION
This parameter is used for enabling the forging for pneumatic circuit welders that envisage this function.
Its enabling adds the Forge Delay parameter to the work program.
PROPORTIONAL VALVE
This parameter is used for welders that envisage the use of a proportional valve and the parameter that
is activated in the program is the Pressure parameter.
PRESSURE TRANSDUCER
With this parameter it is possible to select, if the above parameter is activated, the most suitable BAR/
VOLT ratio for the type of solenoid valve the user intends using.
OPTIONS SIGNAL
RATIO
AMMETER
CAPACITY
X1
150 mV / kA
40 - 90 kA
X5
750 mV / kA
8 - 18 kA
X10
1.5 V / kA
4 - 9 kA
COIL RATIO
This parameter shows the sensitivity of the current transducer installed on the welder.