Subject to technical modifications without prior notice.
TP-20.1 u. 30.1-07/13
26 Learning the end closing points of the door - Programming the power
Attention:
Do not press any buttons or use the hand-held
transmitter during the learning process!
Note: If the learning process for travel path
and power has failed then the points 1-5 in
the instructions must be repeated.
5
Confirm end closing point of door, and begin learning travel path
and power data:
TS
TL
After having selected the closing of the door,
press
TL
constantly for about 5 seconds
until the door begins moving.
Then release the button
TL
.
The constant yellow LED goes off after learning.
OK
Attention! The door moves!
Attention:
The metal stop is the end opening point of the door.
Please see page 23!
It is very important that the metal stop is mounted!
Step 1.
Step 2.
Step 3.
Safety instruction
To exclude any risk of injury, the stated measures from standard EN 12453 and EN 12445
need to be carried out to proof the accurate closing forces.
Please absolutely consider the standards EN 12635 and EN 13241-1 as well.
An additional protection by a closing edge safeguard or by a light barrier needs to be
used in cases where these standards cannot be followed.