Technosoft 2014
31
iPOS360x MX Technical Reference
3.4.5.1
Selection Levels on Axis ID Inputs
On iPOS360x the selection of the operation mode: CANopen or TMLCAN as also of the axis ID
number is done by setting different voltage levels on the inputs AxisID 0 (J2 pin 16), AxisID 1(J2
pin 15) and AxisID 2 (J2 pin 14). Each input can be set to one of the following 7 levels:
Level
Connection needed
L0
Connect input directly to ground (J2 pin 12)
L1
Connect input through a 4.7K
Ω
resistor to ground
L2
Connected input through a 22K
Ω
resistor to ground
L3
Nothing connected
–
leave input open
L4
Connect input through a 22K
Ω
resistor to +5Vdc (J2 pin 13)
L5
Connect input through a 4.7Kohm resistor to +5Vdc
L6
Connect input directly to +5V
The operation mode selection is done via AxisID 2:
CANopen mode, if the input levels are: L0, L1 or L2 (J2 pin 14 going to ground)
TMLCAN mode, if the input levels are L3, L4, L5, L6 (J2 pin 14 floating or going to +5V)
shows how to set the 7 levels on the AxisID 0 input and the resulting axis ID values when
AxisID 2 input level is set for
CANopen
shows how to set all possible values
for axis ID in this mode of operation.
Remarks:
1. AxisID value is computed with formula: 49 x A 7 x A AxisID0, where each
AxisID can have one of the integer values: 0 to 6 (0 for L0, 1 for L1, 2 for L2, etc.)
2. If the resulting AxisID value is 0 (all 3 inputs are connected to GND), the axis ID will be
set to 127. If the resulting AxisID is greater than 127, the axis ID will be set to 255.
3.
If the AxisID is set to 255, the drive remains “non
-
configured” waiting for a CANopen master
to configure it using CiA-305 protocol.
A “non
-
configured” drive answers only to CiA
-305
commands. All other CANopen commands are ignored and transmission of all other
messages (including boot-up) is disabled.
shows how to set the 7 levels on the AxisID 0 input and the resulting axis ID values
when AxisID 2 input level is set for
TMLCAN
operation.
values for axis ID in this mode of operation.
Remarks:
1. AxisID is computed with formula: 49 x (AxisID2 - 3) + 7 x A AxisID0, where each
AxisID can have one of the integer values: 0 to 6 (0 for L0, 1 for L1, 2 for L2, etc.)
2.
If the resulting AxisID value is 0 the axis ID will be set to 255
Содержание iPOS360x MX
Страница 2: ......
Страница 4: ......
Страница 13: ... Technosoft 2014 XI iPOS360x MX Technical Reference This page is empty 1 Safety information ...
Страница 44: ... Technosoft 2014 32 iPOS360x MX Technical Reference Figure 3 4 Axis ID Setting Examples CANopen mode ...
Страница 45: ... Technosoft 2014 33 iPOS360x MX Technical Reference Figure 3 5 Axis ID Setting Examples TMLCAN mode ...
Страница 69: ... Technosoft 2013 57 iPOS360x MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Страница 114: ... Technosoft 2013 102 iPOS360x MX Technical Reference This page is empty ...
Страница 115: ......
Страница 116: ......