Technosoft 2014
21
iPOS360x MX Technical Reference
+5V output current
250
350
mA
Short-circuit protection
NOT protected
Over-voltage protection
NOT protected
ESD protection
Human body model
±1
KV
†
Stresses beyond values listed under “absolute maximum ratings” may cause permanent damage to the device.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Figure 2.13
iPOS3602 MX De-rating with ambient
temperature
Figure 2.14
iPOS3602 MX De-rating with altitude
Figure 2.15
iPOS3602 MX Current De-rating with
PWM frequency
Figure 2.16
iPOS3602 MX Over-current diagram
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
2,2
50
55
60
65
Curr
e
nt
[A
]
Ambient Temperature [ºC]
Temperature De-rating
20KHz 3-
phase
100KHz
3-phase
20KHz 4-
phase
20KHz 3-
phase
24V
100KHz
3-phase
24V
0
0,5
1
1,5
2
2,5
0
1
2
3
4
5
6
7
8
9
10
Curr
e
nt
[A
]
Altitude [Km]
Altitude De-rating
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
2,2
2,4
0 10 20 30 40 50 60 70 80 90 100
Cu
rr
ent
[
A
]
PWM Frequency[KHz]
PWM Frequency De-rating
36V 3-
phase
24V 4-
phase
36V 4-
phase
0
10
20
30
40
50
60
70
0
0,5
1
1,5
2
2,5
3
3,5
Ti
m
e
[s
]
Current [A]
Overcurrent Diagram
I
NOM
= 2 A
I
MAX
= 3.2 A
I
2
T = 250 A
2
s
t
PK
= 24 s
Содержание iPOS360x MX
Страница 2: ......
Страница 4: ......
Страница 13: ... Technosoft 2014 XI iPOS360x MX Technical Reference This page is empty 1 Safety information ...
Страница 44: ... Technosoft 2014 32 iPOS360x MX Technical Reference Figure 3 4 Axis ID Setting Examples CANopen mode ...
Страница 45: ... Technosoft 2014 33 iPOS360x MX Technical Reference Figure 3 5 Axis ID Setting Examples TMLCAN mode ...
Страница 69: ... Technosoft 2013 57 iPOS360x MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Страница 114: ... Technosoft 2013 102 iPOS360x MX Technical Reference This page is empty ...
Страница 115: ......
Страница 116: ......