New Wellness Expert: Service & Maintenance manual - rev. 1.1
8. ADJUSTMENTS
8.1. TOUCH SCREEN CALIBRATION
Two different Touch Screen models are mounted on the products we have on the market, the first
model used was a SEMTECH and the actual one an HAMPSHIRE.
The two models can be distinguished by the revision printed on the Touch Screen interface board
“
CS622 REVA LC
” on the SEMTECH models and “
CS690 REVA LC
” on the HAMPSHIRE
models.
SEMTECH
HAMPSHIRE
Depending on the touch screen model, it has to be used the proper calibration SW.
Unfortunately it is not possible to know which of the two models is mounted on the machine, if you
don’t open the display. Then we can suggest you to proceed as follow, to perform the calibration.
Check if the icon
is shown in the right bottom corner toolbar of the desktop.
If the icon is not present, carry out the calibration procedure 8.1.1. Touch screen first model
“SEMTECH”;
If the icon is present, carry out the calibration procedure 8.1.2. Touch screen second model
“HAMPSHIRE”. If the calibration doesn’t have any effect carry out the calibration procedure
8.1.1. Touch screen first model “SEMTECH”.
Page 8.1
Содержание Wellness Expert
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 1 1 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 1 4 Page intentionally left blank ...
Страница 16: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 2 6 Page intentionally left blank ...
Страница 20: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 3 4 Page intentionally left blank ...
Страница 22: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 4 2 Page intentionally left blank ...
Страница 56: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 8 8 Page intentionally left blank ...
Страница 60: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 9 4 Page intentionally left blank ...
Страница 63: ......