New Wellness Expert: Service & Maintenance manual - rev. 1.1
(3)
Using a tester, check that all the output voltages on connector CN2 of the power supply are
correct, referring to paragraph 2.6. “Wiring”.
(4)
As for step (3) but on connector J5 on the base board.
(5)
As for step (3) but on connector J8 on the base board.
(6)
As for step (3) but on connector CN1 on the LCD inverter board.
(7)
Place the tester probes across the 2 pins of the connector CN02 and CN03 of the LCD inverter
board. The measured voltage should be approximately 340 VAC on CN02 and 180 VAC on
CN03.