New Wellness Expert: Service & Maintenance manual - rev. 1.1
Page 8.2
8.1.1. T
OUCH SCREEN FIRST MODEL
“SEMTECH”
To access the touch screen calibration function, proceed as follows:
1. Click
START
, select
SETTINGS
and then
CONTROL PANEL
.
2. In the window which appears, double click the
Touch Screen calibrator
icon to launch the test
program.
3. The following dialog appears on the display.
Figure 8.1-1
4. Check that the calibration offset is set for 10% and launch the procedure by clicking on
CALIBRATE
.
If the system freeze after the calibration procedure has been launched, it means that the
HAMPSHIRE Touch Screen is mounted on the machine. Restart the system and carry
out the procedure 8.1.2. Touch screen second model “HAMPSHIRE”.
5. The following appears on the display:
Figure 8.1-2
6. Follow the on-screen instructions, touching the centre of each target with an object that is
pointed but not sharp.
Содержание Wellness Expert
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 1 1 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 1 4 Page intentionally left blank ...
Страница 16: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 2 6 Page intentionally left blank ...
Страница 20: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 3 4 Page intentionally left blank ...
Страница 22: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 4 2 Page intentionally left blank ...
Страница 56: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 8 8 Page intentionally left blank ...
Страница 60: ...New Wellness Expert Service Maintenance manual rev 1 1 Page 9 4 Page intentionally left blank ...
Страница 63: ......