6.10.
THERE IS NO RESISTANCE
The machine will not produce resistance if:
•
the display board is not receiving a speed signal;
•
the brake board is not generating current;
•
the brake is defective.
Does the brake board supply
tension at the brake?
THERE IS NO
RESISTANCE
Are the Watt and SPM v alues
shown on the display dif f erent
f rom zero?
NO
YES
1
Carry out the "The speed
signal is incorrect"
troubleshooting procedure
Replace the brake board
YES
Does the input of brake receiv e
tension f rom the brake?
NO
Replace the brake
YES
Replace
ELT-02 cable
NO
3
YES
Is the resistance on the Brake
winding
more or less 5 Ohm?
Replace the brake
NO
2
SE