SYNCHRO EXCITE Class & Trend: Service & maintenance manual - rev. 2.0
Page 9.27
9.4.3.3.
COM.Fault
This is a counter that display the number of errors in serial communication between the upper and
the lower kit. This counter increase each time a communication fault is detected. Scroll using the
+/- keys until the display shows:
COM.FAULT X
To reset it press
ENTER
, the LED display shows:
RESET COM.FAULT?
press
ENTER
to reset and return to the upper menu level by pressing
CLEAR
for a few seconds.
9.4.3.4.
View Errors
For every error generated by the machine, the error history log records the information in the table
below:
•
Counter
•
Error code
•
Current when the error occurred
•
Distance in km when the error occurred
The correspondence between error codes and descriptions is given in the table below:
Error Code Description
1
OVERHEATING:
this condition occurs when the temperature detected by the
sensor on the circuit board exceeds 90°C.
2
OVERCURRENT:
this condition occurs when the Brake board detects an
excessive amount of current being sent to the winding.
8
OVERVOLTAGE:
this condition occurs when the +12 Vdc voltage goes above
13.7 Vdc (only on the 500, 700, and 700WTV models).
16
SOLENOID OVERHEATING:
this condition occurs when the NTC, connected
in series with the solenoid, detects a temperature higher than 140°C and opens the
circuit.
32
EPROM
: SW error on the Brake board (braking table).
128
REFERENCE VOLTAGE FAULT:
this error condition occurs when the
calibration parameter stored in the Brake board is incorrect.
Use the
+
effort level key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.
Содержание Synchro Excite 500
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 0 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...SYNCHRO EXCITE Class Trend Service maintenance manual rev 2 0 Pagina vi Page intentionally left blank ...
Страница 48: ...SYNCHRO EXCITE Class Trend Service maintenance manual rev 2 0 Pagina 4 6 LIBYA DVB T ...
Страница 49: ...SYNCHRO EXCITE Class Trend Service maintenance manual rev 2 0 Page 4 7 Page intentionally left blank ...
Страница 50: ......
Страница 190: ...SYNCHRO EXCITE Class Trend Service maintenance manual rev 2 0 Pagina 9 50 Page intentionally left blank ...
Страница 201: ......