NOTE: Please follow the instructions provided in the section “Cleanout, disassembling and reassembling
of parts in contact with the product” when performing this operation
1)
Wash all the disassembled parts in hot water (50°C) with detergent (e.g.
DIVER SEY – SU891
available in Italy or
DIVER SEY – VK3L
available in other countries) using a concentration of the
product
between
5 ÷ 10%
.
2)
Use the three-bowl sink to wash, rinse and sanitize all the disassembled parts. For sanitizing u
se acid
(
e.g. Percitric or Peracetic
)
so as to obtain a final concentration of
0,1
÷
0,3%
in cold water,
max 25°C
,
to sanitize the parts. Leave the parts to soak in the sanitizing solution for five minutes (no more than
fifteen). Leave the parts to dry naturally on the draining board,
without using sponges or tea-
towels.
Sanitizing the machine
The reassembled machine must be sanitized before refilling it with a new mix.
The washing and sanitizing procedure must comply with what foreseen by your local and/or state Health
Authorities. If you are uncertain of these regulations, verify what specified by the Federal, state, or local
regulatory AHJ.
3)
It is extremely important to sanitize your machine. This procedure will delay the growth of bacteria and
will allow you to pass all the tests that your local Health Authority imposes.
4)
Fill in the tank with cold water once again, max 25°C and then add the sanitizer,
acid
(e.g.
Percitric
or
Peracetic
) so as to obtain a final concentration of
0,1
÷
0,3%
5)
Leave the sanitizer solution for a maximum of 15 mins. to allow it to perform its action making sure
that all the surfaces which will come into contact with the finished product are treated with the
solution.
6)
Drain the sanitizer from the tank by turning on the faucet; if desired, use part of the solution to sanitize
all the components described in point 7.
7) Rinse the tank thoroughly using copious clean water (minimum 20/30 LT)
IMPORTANT:
Do not exceed in the dose of the sanitizing product (please check the indications above)
NEVER USE CHLORINE when performing this operation as it could damage the plastic parts
and corrode the stainless steel walls.
Never leave the sanitizing solution in the machine for over one hour to avoid any corrosion of
the parts.
Never use cloths and never touch the sanitized parts with your hands as this will
contaminate them.
The machine is now ready to be filled with a new liquid mix.
Содержание MIXTRONIC 110
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 19: ...19 ...
Страница 37: ...37 TROUBLESHOOTING ...
Страница 44: ...44 General electric panel MIXTRONIC 60 110 220V 60 HZ ...
Страница 46: ...46 Legend MIXTRONIC 110 ...
Страница 56: ...56 ...
Страница 57: ...57 E EL LE EC CT TR RI IC C S SI IS ST TE EM M ...
Страница 58: ...58 ...
Страница 59: ...59 ...
Страница 60: ...60 ...
Страница 61: ...61 ...
Страница 62: ...62 ...
Страница 63: ...63 ...
Страница 64: ...64 ...
Страница 65: ...65 ...