2-9
2.4
REMOTE OPERATION SET UP
The Procedures listed below enable the user to custom configure the unit for external remote
control hardware. Refer to Table 2-1 for connector pin details on Remote Control D Connector
located at rear of Case Assembly and Table 2-2 for Jumper Functions.
The Record audio output and Remote audio line level is factory set for -8 dBm. Trimpot resistor
R26 (Record) is adjustable over the range of +10 dBm to -20 dBm. Trimpot resistor R35
(Remote Audio) adjusts levels over the range of +10 dBm to -15 dBm.
Transmitter keying can be set for ground keying or ± DC keying. In ± DC keying, a positive
voltage b10 Vdc and +48 Vdc or negative voltage between -10 Vdc and -48 Vdc
will key the transmitter. A DC voltage between -5 Vdc and +5 Vdc will not key the
transmitter.
(1)
Remove Cover from Case Assembly. Refer to paragraph 2.1.1.
CAUTION
This unit contains static sensitive devices. Wear a
grounding strap and/or conductive gloves when
handling printed circuit boards.
(2)
Position Jumpers on Control board as indicated in Table 2-2. Refer to Figure 2-3 for
jumper locations.
NOTE
Jumpers J1, and J2 must be in one of the Locations
shown in Table 2-2 for Press-To-Talk (PTT) Operation.
(3)
Replace Cover on Case Assembly. Refer to paragraph 2.1.2.
(4)
Verify Remote Control operation in accordance with manufacturers instructions.
Содержание TiL-91-DE/S
Страница 6: ...1 2 Figure 1 1 TPS 250 Portable Transceiver General View Closed Open View...
Страница 7: ...1 3 Figure 1 2 Transceiver Front Cover Assembly...
Страница 14: ...2 2 Figure 2 1 Battery Installation and Removal...
Страница 18: ...2 6 Figure 2 2 Fixed Channel Jumper Locations...
Страница 20: ...2 8 Figure 2 3 Remote Operation Jumper Locations...
Страница 25: ...3 2 Figure 3 2 Transceiver Front and Rear Panel Layout...