AccuLoad IV Installation & Maintenance Manual
Introduction
1
1 Introduction
This manual provides guidance for the electrical installation and general maintenance of the Smith Meter
AccuLoad IV. When installed following the guidelines contained in this manual, the AccuLoad should
provide many years of safe, accurate, and reliable use.
This manual addresses the requirements specific to the AccuLoad IV and it is assumed that the installation
designers and fabricators are familiar with the applicable industrial facility construction standards specific to
the particular facility. The ST and QT models are designed for use in Class 1, Division 1 and Zone 1
hazardous locations, while the N4 and SA models are designed for North American Class 1, Division 2
environments only. If questions arise, please contact our Field Service Response Center or Customer
Support.
1.1 Product Description
The AccuLoad provides accurate, reliable control and measurement of liquid petroleum blending and
transfer operations. While primarily intended for use in refined petroleum distribution terminals, it can be
easily configured for a wide variety of liquid transfer applications.
Operators can select an amount of product to transfer and the AccuLoad monitors and controls the
configured pumps, valves, and additive injectors to safely and efficiently transfer the precise recipe and
amount. During the transfer, all processing parameters are monitored to provide operators with an
accurate amount of each component of the recipe delivered.
In addition to real-time control of the loading process, the AccuLoad also calculates averages and live
quantities of all products and additives delivered. This information is stored in a runtime database that can
be monitored by a supervisory host system. Whenever a transaction is completed, the AccuLoad stores a
detailed record in an internal transaction log for subsequent retrieval or printing.
1.1.1 AccuLoad IV Models
The AccuLoad IV is available in several hardware configurations and with multiple standard and optional
modules.
1.1.1.1 AccuLoad IV ST
The Single Touch Screen (ST) model
has the following specifications:
•
Explosion-proof enclosure
•
Two-arm operation
•
Up to four single- or dual-pulse product meter inputs
•
Up to four additive meter inputs or, with the optional A4I module, up to 24 additive meter inputs
•
AccuLoad III to IV upgrade kit (UG3)
Содержание Smith Meter AccuLoad IV
Страница 7: ...AccuLoad IV Installation Maintenance Manual Introduction 2 Figure 1 AccuLoad IV ST ...
Страница 9: ...AccuLoad IV Installation Maintenance Manual Introduction 4 Figure 3 AccuLoad IV QT ...
Страница 11: ...AccuLoad IV Installation Maintenance Manual Introduction 6 Figure 5 AccuLoad IV N4 ...
Страница 14: ...AccuLoad IV Installation Maintenance Manual Introduction 9 Figure 8 AccuLoad IV SA FCM ...